TEST & CONTROL
TESTING DEPT.
– Hydro test up to 30000 psi
– Gas test up to 15000 psi
FARO GAGE
Our dimensional inspections are performed in accordance with internal procedures by qualified personnel
PMI
POSITIVE MATERIAL IDENTIFICATION Material traceability is ensured by controls performed by internal personnel or external laboratories
NDE
Non distructive methods aviable:
– PT: DYE PENETRANT TEST
– RT: RADIOGRAPHIC EXAM
– UT: ULTRASONIC TEST
– VT: VISUAL TEST
– MT: MAGNETOSCOPIC TEST